Fire Alarm Systems

 

B6-SCP 1020

B6-SCP 1020

SecuriFire 1000 is a stand-alone fire alarm control panel and is suitable for connecting an addressable loop with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus.

read more

B7-SCP 520

B7-SCP 520

SecuriFire 500 is a compact, stand-alone fire alarm control panel and is suitable for connecting a SecuriLine eXtended addressable loop with up to 250 participants. The control panel is equipped with a 5,7″ LCD color screen and with all the necessary interfaces for connection to the fire brigade. It has relay outputs and a connection for the external device bus. The control panel has more than 20 languages available in the same time, including Romanian.

read more

B6-SCP 2030

B6-SCP 2030

SecuriFire 2000 is a compact networkcompatible fire alarm control panel and is suitable for connecting up to 4 addressable loops with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus.

read more

B5-SCP 3030

B5-SCP 3030

SecuriFire 3000 is a modular network-compatible fire alarm control panel and is suitable for connecting up to 16 SecuriLine eXtended addressable loops with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus. The multilingual MIC11 operating [...]

read more

Multi Criteria Detector

Multi Criteria Detector

The MCD 573X is a hybrid fire detector: The temperature-supported smoke sensor provides early detection of smouldering, glowing and open fires with smoke development. Smoke sensitivity adapts to the prevailing ambient temperatures in the area and automatically regulates smoke sensitivity (Cubus Adaptation). The temperature sensor also detects fire with no smoke development when fires break out rapidly with high temperatures. The smoke detection system offers 2 programmable advance alarm [...]

read more

Combined smoke, heat and CO detector

Combined smoke, heat and CO detector

The CCD 573X is a combined smoke-, heat- and carbon monoxide detector. It detects smouldering fires and open fires early on by detecting and evaluating the fire characteristics smoke, heat and carbon monoxide (CO). Smoke is detected using the Tyndall principle (scattered light), heat is detected using the NTC sensor principle, and an electrochemical sensor [...]

read more

BSE 128

BSE 128

Acoustic alarm medium in a robust construction for general use. The sound volume can be adjusted via potentiometer. It is able to generate 28 different melodies. The setting of the tone is done via DIL-switch. Optionally, a second tone can be activated via separate input. The 2nd tone melody depends on the setting for the first tone.

read more

MMD 130 Ex-i

MMD 130 Ex-i

An intrinsically safe smoke detector for use in hazardous areas of zone 1 and zone 2 and certified to classification II 2 G Ex ib IIC T4. The MMD 130 Ex-i works in accordance with the scattered light principle and detects smouldering, glowing   and   open  fires  with   smoke  development   at  an early stage.

read more

ROLP SB

ROLP SB

The ROLP SB combined audible and optical LED sig-nal transmitter can be connected to the SecuriFire control panels. The ROLP SB signal transmitter audibly and optically signals a fire alarm indoors; the IP 65 variant works as well out-doors. The ROLP SB  can be connected directly to the fire detector line along with other participants via [...]

read more

BX-SOL

BX-SOL

The BX-SOL can be connected directly to the fire alarm line. The volume can be set to either “Low” or “High” and the tone type is set via the fire alarm control panel, even during ongoing operation, depending on the event. The siren is available in the colours red and white and corresponds to environmental category [...]

read more

BX-SBL

BX-SBL

The Loop Siren BX-SBL 502 is an addressable alarm unit for the acoustic alarming of a fire alarm in indoor applications.  The Loop Siren unit BX-SBL 502 can be connected directly to the fire alarm loop, mixed with other participants such as manual call points or automatic fire detectors.

read more

BX-AIM

BX-AIM

The BX-AIM can be connected to the SecuriLine eXtended ring circuit of the SecuriFire 500/1000/2000/3000 fire detection systems. The BX-AIM can be used either as monitored input for polling potential-free contacts or as detection zone for connecting col-lective detectors. It serves, among other things, to connect intrinsically safe detec-tors (Ex-i) with intermediate switching of a Zener barrier. An [...]

read more

RAL 720X

RAL 720X

Alarm indication of fire detectors which are not directly visible e.g. behind doors or which are mounted in a hidden place e.g. false ceiling. Activation from detector output or via appropriate output module.

read more

BX-IM4

BX-IM4

For indication and monitoring of various types of acknowledgements, e.g. door contacts, fire zones, extinguishing systems, sprinkler messages, etc. The module contains 4 inputs for monitored and non-monitoring querying of potential-free contacts, which are suitable for processing switching states of longer than 330ms. Both the addressing of the module and the setting of its parameters, which are set separately for every input, [...]

read more

BX-REL4

BX-REL4

Provides for four potential free relay outputs with a contact rating of 2A to 230V. Each relay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. Each input is freely programmable using SecuriFire Studio. The module is also suitable for emitting switching impulses. The relay outputs can be switched to a fail-safe position in the event of voltage loss on the [...]

read more

BX-IOM

BX-IOM

For controlling monitored devices, which are supplied with power by an external power supply (e.g. sirens etc.). The module contains a short circuite resistant monitored output (suitable for continuous operation of fur a configurable pulse emmision with emission time limitation) and galvanically isolated input which can be used either as a voltage on the loop circuite is internally monitored for undervoltage. Both [...]

read more

BX-OI3

BX-OI3

Contains a relay output with a programmable fail-safe position, two inputs for monitored querying of potential-free contacts and an optocoupler input for monitoring external voltages. In addition, the voltage on the loop circuit is internally monitored for low voltage. The BX-OI3 is particularly well-suited for connecting special detectors (flame and line detectors, smoke aspirating systems etc.). Both the addressing of the module [...]

read more

SDI 82X-1

SDI 82X-1

Addressable   I/O  module,   typically  connected   to  Manual Call points (MCP), Pull Stations, Smoke Switches or Door monitors. For SecuriLine eXtended emergency alarm transmission. Provides   3   inputs   and   1  open   collector   output,   freely programmable.

read more

BX-ESL

BX-ESL

End position switch for deployment in sprinkler monitoring and for blocking systems. The module contains an optical light barrier which measures the movement of an activation plunger. The cables are fed into the unit using PG connection joints, with connection to the loop module being via 3 screw-type terminals. Both the addressing of the module and the setting of its parameters [...]

read more

BX-O2I4

BX-O2I4

The BX-O2I4 has two relay outputs and four monitored inputs for polling potential-free contacts. The individual I/O functions can be configured differently and combined so that this module can be used, for example, for the integration of fire protection flaps with feedback. Addressing and parameter assignment for the BX-O2I4 is performed with PC software via the fire alarm control panel. The module includes a [...]

read more

MCP 545X-1N

MCP 545X-1N

The manual  call  point  MCP  545X N is a non automatic detector for fire alarm systems for direct connection to the SecuriLine / eXtended. An alarm is triggered directly when the  glass  panel is  broken. The   alarm   persists  until  the glass panel is replaced with a new one. Alarm triggering is indicated by means of a red LED. For test purposes, [...]

read more

MCP 521-1N

MCP 521-1N

The manual call point MCP 521 N is a non-automatic detector for fire alarm systems with current amplification line evaluation. An alarm is triggered directly by breaking the glass panel (type A). The alarm remains until the glass panel is replaced with a new one. For test purposes, an alarm can be triggered by means of a test key without breaking [...]

read more

MCP 535x

MCP 535x

The manual call point MCP 535X is a non automatic detector for fire alarm systems for direct connection to the SecuriLine / eXtended. The desired signal is triggered by breaking the glass panel and pushing the button. The push button can only be reset after the alarm button has been deblocked. For the stop device variant, there is no blocking mechanism [...]

read more

B5 DXI2

B5 DXI2

Interface for two SecuriLine eXtended loops (250 Devices per loop). Alternatively one loop circuit and two stub lines or four stub lines can be connected. -    Provides loop control and data logging; -    Detectors can be linked via modules and subcontrol units; -    Disablement of individual detectors; -    Evaluation of detector states (contamination recognition); -    Monitoring of all [...]

read more

B5 NET2 485

B5 NET2 485

For redundant networking SecuriFire control panels or for redundant connection of PC applications. The module consists of two network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 6 RJ 45 sockets for connecting from the sub control unit network and to the Ethernet. The module can only be fitted in connection slot 2 [...]

read more

B5 NET4 485

B5 NET4 485

For redundant networking of SecuriFire control panels or for redundant connection of PC applications. The module consists of four network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 10 RJ45 sockets for connecting from the sub control unit network and to the Ethernet. The module can only be fitted in connection slot 2 [...]

read more

B5 BAF

B5 BAF

For connecting fire brigade control panels, transmission equipment (main detectors), alarm systems (sirens) and for controlling the relay bus. The module also controls an interface for the MMI-BUS (bus for external devices) to which external operating panels, a fire brigade operating panel and other devices are connected.

read more

B5 LAN

B5 LAN

For non-redundant networking of SecuriFire control panels and for non-redundant connection of PC applications. Two 8 pole RJ-45 sockets can be found on the front side of the module. The module can only be fitted in connection slot 2 in the module rack.

read more

B3 USI4

B3 USI4

For connecting SecuriFire sub control units to control systems, for controlling external printers, pagers, ComBOX units, telephone servers etc. A total of 4 redundant, serial, asynchronous interfaces can be used as redundant RS 485 connections in half-duplex mode (for loops) or as non-redundant RS 422 connections in full-duplex mode (for lines). Furthermore, two of the four interfaces can also be operated [...]

read more

B3-OM8

B3-OM8

This indicating Circuit Controller is designed for efficient, addressable control of sounders, sirens, bells and strobes. The maximum output current of 1,3 A per output and 3A per block of four lines (1 to 4 and 5 to 8) assures meeting all requirements for signalling devices. The outputs are monitored for short circuits and wire breaks. Note: The total output current [...]

read more

B3 IM8

B3 IM8

The B3-IM8 is designed to provide an interface between conventional detectors and the SecuriFire panel. It enables the panel to use each of the eight channels individually to monitor the presence and operation of up to 32 conventional detectors per channel (max. 256 detectors) monitor the presence and operation of up to 10 Ex detectors in intrinsically safe applications using Z787 safety [...]

read more

B3 LEE23

B3 LEE23

For connecting up to eight stub lines each with a maximum of 30 series 140 detectors. A maximum of five B3-LEE23 modules can be fitted to connection slots 2 to 8 of a SecuriFire module rack, however this module is only permitted for use in cases where the system is being reconditioned due to the terms of the approvals of [...]

read more

B3 LEE24

B3 LEE24

Refurbishing module for old installations based on HX 150 detectors. Provides four (4) addressable loops supporting HX protocol and 127 HX 150 detectors each. A maximum of five B3-LEE24 modules can be plugged in slots 2 to 8 of the SecuriFire module rack.

read more

B3 REL10

B3 REL10

The module contains 10 bistable, freely programmable 230V/3 A relay contacts. Whether a contact is a make contact or a break contact is ascertained by configuration using software. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being switched off. A [...]

read more

B3 REL16

B3 REL16

The module contains 16 bi-stable, freely programmable 24 V/3 A relay contacts and is used for controlling sirens, holding magnets, relays etc. Whether the contact is a make or break contact is determined by software-based programming. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire [...]

read more

B3 REL16E

B3 REL16E

The module contains 16 bi-stable, freely programmable 24 V/3 A relay contacts and is used for controlling sirens, holding magnets, relays etc. Whether the contact is a make or break contact is determined by software-based programming. By programming a fail-safe position the status of every individual relay can be defined in the event of a [...]

read more

B5 MRI16

B5 MRI16

The module offers 16 bi-stable, freely programmable 24 V/3 A relay contacts. Whether a contact is Normally Open (NO) or Normally Closed (NC) is software configurable. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being [...]

read more

B5-MIC711

B5-MIC711

External   main  indication   and  control  panel  for SecuriFire 3000. User-friendly full operation with “SecuriWheel” and system symbols. Characteristics: -    In SecuriFire LAN integrable; -    5.7“ TFT-Colour Display; -    Customized menus (optional); -    Operation with scroll wheel or functional keys; -    4 different languages changeable online; -    Up to 1200-m distance    between MIC711 and central; -    Redundant by [...]

read more

B5-MMI-FIP

B5-MMI-FIP

The SecuriFire floor indication panel provide well organised and convenient announcement of the conditions of the SecuriFire – system. It contains a monochrome LCD display with 6 lines for the indication   of  all  investment  conditions   in  the  clear   text. No   inscription    on   housing    front   (only   announcement elements). Characteristics: -    Connection to MMI-BUS; -    Up to 1200m distance between FIP and central possible; [...]

read more

B6-LXI2

B6-LXI2

For connecting a further two addressable loops with detectors and modules featuring SecuriLine eXtended addressable loop technology to the SecuriFire 2000. Alternatively one addressable loop and two stub lines or four stub lines can also be connected. The unit also has a LAN interface. This means that all the options of a LAN interface can be used even with 4 loops. [...]

read more

B6-NET2-485

B6-NET2-485

(Română) Paca de retea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-EIO

B6-EIO

The   B6-EIO   Unit  includes   10   monitored   inputs   and   8 monitored outputs as well as the control electronics for the LED indication panel, which is built into the door of every SecuriFire ECP/FEP 2000. The unit was developed for standards-compliant actuation of an extinguishing area. However, in accordance with its features, it can also be used in other ways.

read more

B3-DCI6

B3-DCI6

The B3-DCI6 is used for supplying and evaluating up to 6 inputs, which can be set either as detector zones using DC technology, as monitored inputs or as extinguisher inputs (e.g. VdS extinguishing interface, primary  inputs, valve monitoring etc.) via jumper caps and via programming. It is possible to differentiate between a maximum of ten detector areas by  means of  an [...]

read more

B6-MIC 711

B6-MIC 711

External non redundant main indication and control panel for SecuriFire 2000. User-friendly full operation with “SecuriWheel” and system symbols.

read more

BX-O1

BX-O1

Provides one potential free relay outputs with a contact rating of 2A @ 230V. Each input is freely programmable using SecuriFire Studio. The module is also suitable for emitting switching impulses. The relay output can be switched to a fail-safe position in the event of voltage loss on the loop circuit, and the voltage on the loop circuit is also internally [...]

read more

BX-I2

BX-I2

(Română) Modul cu doua intrări monitorizate.

read more

B4-USI

B4-USI

(Română) B4-USI este o unitate de comunicare universală pentru centralele SecuriFire seria 2000.

read more

B6-LAN

B6-LAN

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-NET2-FXS

B6-NET2-FXS

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-NET2-FXM

B6-NET2-FXM

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more

XLM 35

XLM 35

(Română) Modul pentru conectarea detectorului de fum prin aspirație ASD la bucla de incendiu.

read more

Flame detector

Flame detector

The family of infrared flame detectors is suitable for the detection of open fires.

read more

Test spray

Test spray

For functional testing of smoke detectors. Lasts for approx. 200 tests. Free of halogenated hydrocarbons.

read more

EXBAR Z787

EXBAR Z787

The safety barriers for intrinsically safe detector zones prevent too high an energy level from entering a hazardous area, which could cause ignition sparks if discharged there. The barrier is connected in series into the wiring of the detector zone. The device is ATEX 100a approved.

read more

SCD 563

SCD 563

The SecuriStar® SCD 563 scattered-light smoke detector with digital signal processing and intelligent evaluation logic has excellent response behaviour and a very low false alarm rate. The response behaviour adapts automatically to prevailing ambient temperatures. The SCD 563 is designed for connection to conventional control panels evaluating a rise in current.

read more

TCD 563

TCD 563

The SecuriStar® TCD 563 universal temperature detector is deployed wherever a smoke detector cannot be used due to ambient conditions. The TCD 563 is designed for connection to conventional control panels evaluating a rise in current.

read more

MCP 525

MCP 525

MCP 525 manual call points are for installation in fire alarm systems to allow the alarm to be raised manually. They are installed in 2-wire alarm circuits with current amplification.

read more