Fire Alarm Control Panels

Generatia noua de centrale SecuriFire corespund noilor norme Europene 

B6-SCP 1020

B6-SCP 1020

SecuriFire 1000 is a stand-alone fire alarm control panel and is suitable for connecting an addressable loop with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus.

read more

B7-SCP 520

B7-SCP 520

SecuriFire 500 is a compact, stand-alone fire alarm control panel and is suitable for connecting a SecuriLine eXtended addressable loop with up to 250 participants. The control panel is equipped with a 5,7″ LCD color screen and with all the necessary interfaces for connection to the fire brigade. It has relay outputs and a connection for the external device bus. The control panel has more than 20 languages available in the same time, including Romanian.

read more

B6-SCP 2030

B6-SCP 2030

SecuriFire 2000 is a compact networkcompatible fire alarm control panel and is suitable for connecting up to 4 addressable loops with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus.

read more

B5-SCP 3030

B5-SCP 3030

SecuriFire 3000 is a modular network-compatible fire alarm control panel and is suitable for connecting up to 16 SecuriLine eXtended addressable loops with up to 250 participants. The control panel is equipped with all the necessary interfaces for connection to the fire services, and with relay outputs and a connection for the external device bus. The multilingual MIC11 operating [...]

read more

B5 DXI2

B5 DXI2

Interface for two SecuriLine eXtended loops (250 Devices per loop). Alternatively one loop circuit and two stub lines or four stub lines can be connected. -    Provides loop control and data logging; -    Detectors can be linked via modules and subcontrol units; -    Disablement of individual detectors; -    Evaluation of detector states (contamination recognition); -    Monitoring of all [...]

read more

B5 NET2 485

B5 NET2 485

For redundant networking SecuriFire control panels or for redundant connection of PC applications. The module consists of two network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 6 RJ 45 sockets for connecting from the sub control unit network and to the Ethernet. The module can only be fitted in connection slot 2 [...]

read more

B5 NET4 485

B5 NET4 485

For redundant networking of SecuriFire control panels or for redundant connection of PC applications. The module consists of four network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 10 RJ45 sockets for connecting from the sub control unit network and to the Ethernet. The module can only be fitted in connection slot 2 [...]

read more

B5 BAF

B5 BAF

For connecting fire brigade control panels, transmission equipment (main detectors), alarm systems (sirens) and for controlling the relay bus. The module also controls an interface for the MMI-BUS (bus for external devices) to which external operating panels, a fire brigade operating panel and other devices are connected.

read more

B5 LAN

B5 LAN

For non-redundant networking of SecuriFire control panels and for non-redundant connection of PC applications. Two 8 pole RJ-45 sockets can be found on the front side of the module. The module can only be fitted in connection slot 2 in the module rack.

read more

B3 USI4

B3 USI4

For connecting SecuriFire sub control units to control systems, for controlling external printers, pagers, ComBOX units, telephone servers etc. A total of 4 redundant, serial, asynchronous interfaces can be used as redundant RS 485 connections in half-duplex mode (for loops) or as non-redundant RS 422 connections in full-duplex mode (for lines). Furthermore, two of the four interfaces can also be operated [...]

read more

B3-OM8

B3-OM8

This indicating Circuit Controller is designed for efficient, addressable control of sounders, sirens, bells and strobes. The maximum output current of 1,3 A per output and 3A per block of four lines (1 to 4 and 5 to 8) assures meeting all requirements for signalling devices. The outputs are monitored for short circuits and wire breaks. Note: The total output current [...]

read more

B3 IM8

B3 IM8

The B3-IM8 is designed to provide an interface between conventional detectors and the SecuriFire panel. It enables the panel to use each of the eight channels individually to monitor the presence and operation of up to 32 conventional detectors per channel (max. 256 detectors) monitor the presence and operation of up to 10 Ex detectors in intrinsically safe applications using Z787 safety [...]

read more

B3 LEE23

B3 LEE23

For connecting up to eight stub lines each with a maximum of 30 series 140 detectors. A maximum of five B3-LEE23 modules can be fitted to connection slots 2 to 8 of a SecuriFire module rack, however this module is only permitted for use in cases where the system is being reconditioned due to the terms of the approvals of [...]

read more

B3 LEE24

B3 LEE24

Refurbishing module for old installations based on HX 150 detectors. Provides four (4) addressable loops supporting HX protocol and 127 HX 150 detectors each. A maximum of five B3-LEE24 modules can be plugged in slots 2 to 8 of the SecuriFire module rack.

read more

B3 REL10

B3 REL10

The module contains 10 bistable, freely programmable 230V/3 A relay contacts. Whether a contact is a make contact or a break contact is ascertained by configuration using software. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being switched off. A [...]

read more

B3 REL16

B3 REL16

The module contains 16 bi-stable, freely programmable 24 V/3 A relay contacts and is used for controlling sirens, holding magnets, relays etc. Whether the contact is a make or break contact is determined by software-based programming. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire [...]

read more

B3 REL16E

B3 REL16E

The module contains 16 bi-stable, freely programmable 24 V/3 A relay contacts and is used for controlling sirens, holding magnets, relays etc. Whether the contact is a make or break contact is determined by software-based programming. By programming a fail-safe position the status of every individual relay can be defined in the event of a [...]

read more

B5 MRI16

B5 MRI16

The module offers 16 bi-stable, freely programmable 24 V/3 A relay contacts. Whether a contact is Normally Open (NO) or Normally Closed (NC) is software configurable. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being [...]

read more

B5-MIC711

B5-MIC711

External   main  indication   and  control  panel  for SecuriFire 3000. User-friendly full operation with “SecuriWheel” and system symbols. Characteristics: -    In SecuriFire LAN integrable; -    5.7“ TFT-Colour Display; -    Customized menus (optional); -    Operation with scroll wheel or functional keys; -    4 different languages changeable online; -    Up to 1200-m distance    between MIC711 and central; -    Redundant by [...]

read more

B5-MMI-FIP

B5-MMI-FIP

The SecuriFire floor indication panel provide well organised and convenient announcement of the conditions of the SecuriFire – system. It contains a monochrome LCD display with 6 lines for the indication   of  all  investment  conditions   in  the  clear   text. No   inscription    on   housing    front   (only   announcement elements). Characteristics: -    Connection to MMI-BUS; -    Up to 1200m distance between FIP and central possible; [...]

read more

B6-LXI2

B6-LXI2

For connecting a further two addressable loops with detectors and modules featuring SecuriLine eXtended addressable loop technology to the SecuriFire 2000. Alternatively one addressable loop and two stub lines or four stub lines can also be connected. The unit also has a LAN interface. This means that all the options of a LAN interface can be used even with 4 loops. [...]

read more

B6-NET2-485

B6-NET2-485

(Română) Paca de retea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-EIO

B6-EIO

The   B6-EIO   Unit  includes   10   monitored   inputs   and   8 monitored outputs as well as the control electronics for the LED indication panel, which is built into the door of every SecuriFire ECP/FEP 2000. The unit was developed for standards-compliant actuation of an extinguishing area. However, in accordance with its features, it can also be used in other ways.

read more

B3-DCI6

B3-DCI6

The B3-DCI6 is used for supplying and evaluating up to 6 inputs, which can be set either as detector zones using DC technology, as monitored inputs or as extinguisher inputs (e.g. VdS extinguishing interface, primary  inputs, valve monitoring etc.) via jumper caps and via programming. It is possible to differentiate between a maximum of ten detector areas by  means of  an [...]

read more

B6-MIC 711

B6-MIC 711

External non redundant main indication and control panel for SecuriFire 2000. User-friendly full operation with “SecuriWheel” and system symbols.

read more

B4-USI

B4-USI

(Română) B4-USI este o unitate de comunicare universală pentru centralele SecuriFire seria 2000.

read more

B6-LAN

B6-LAN

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-NET2-FXS

B6-NET2-FXS

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more

B6-NET2-FXM

B6-NET2-FXM

(Română) Placă de rețea pentru centralele de incendiu SecuriFire seria 2000.

read more